NTSCGECWOEU Medium-Voltage Shearer Power Cable

APPLICATION
NTSCGECWOEU cables are used for the connection of mobile electrical equipment in underground mines, e.g. for coal-cutting machines, especially for the use in chains with extreme bending loads under low tensile stress.

NTSCGECWOEU Medium-Voltage Shearer Power Cable

NTSCGECWOEU Medium-Voltage Shearer Power Cable Application

NTSCGECWOEU Medium-Voltage Shearer Power Cable is used for the connection of mobile electrical equipment in underground mines, e.g. for coal-cutting machines, especially for the use in cable and hose guidance(bretby) chains with extreme bending loads under low tensile stress.

NTSCGECWOEU is designed for the connection of electrical equipment, in mines and underground excavations with hazardous environments under particularly high mechanical loads, e.g.high-voltage transformers on power lines in underground mining and tunneling.

The flexibility of the cable allows operating equipment to be moved while running. The phase-concentric earth conductor and the common concentric monitoring shield,e.g. in conjunction with a high-voltage protection circuit, make it possible to monitor the cable for insulation faults and damage resulting from external influences.

These shearer power cables are used in underground mines as well as in tunnels if monitoring of outer damages is required. The robust construction allows the cable to be used on mobile equipment, on energy lines, as well as for occasional reeling.

NTSCGECWOEU Medium-Voltage Shearer Power Cable Construction

NTSCGECWOEU Medium-Voltage Shearer Power Cable Construction

System1 (1.8/3kV or 3.6/6kV) Flexible stranded tinned copper conductor with heat resistant3GI3 rubber based on EPR, fiberglass and easy strippable outer conductive layer.
System2 (0.6/1kV) Flexible stranded tinned copper conductor with heatresistant3GI3 rubber based on EPR.
Earth Conductor Spiral of tinned copper wire.
Center Bundle Control and pilot cores with copper/steel conductors capable of expansion and compression, EPR insulation, semi-conductive optional with fiber optics, covered with a semi-conductive rubber sheath.
Inner Sheath 2 layer design, semi-conductive rubber + Rubber type 5GM5.
Armour Spiral of steel wires, embedded in the outer sheath, a tape which prevents sheath exchanging.
Outer Sheath Rubber type 5GM5, abrasion, and tear resistant, oil resistant and flame retard fiberglass

NTSCGECWOEU Medium-Voltage Shearer Power Cable Technical Data

Oil resistance Yes
Flame retardant Yes
Max. conductor temperature in service 90°C
Limit surface temperature fixed installed -40 .. 80°C
Limit surface temperature, flexible application -25 .. 80°C
Bending factor when installed 4(xD)
Dynamic bending radius 7.5(xD)

NTSCGECWOEU Medium-Voltage Shearer Power Cable Specifications

1.8/3KV

Number of Cores×
Nominal Cross Section
Minimium Overall
Diameter
Maximum Overall
Diameter
Nominal
Weight
No.×mm² mm mm kg/km
3×50+3×(35+35/3)+2×(2×0.75ST)+2×0.75UEL 62 66 7210
3×70+3×(50+50/3)+2×(2×0.75ST)+2×0.75UEL 64 68 8200
3×95+3×(70+70/3)+2×(2×0.75ST)+2×0.75UEL 74 78 10300

3.6/6KV

Number of Cores×
Nominal Cross Section
Minimium Overall
Diameter
Maximum Overall
Diameter
Nominal
Weight
No.×mm² mm mm kg/km
3×35+3×(35+35/3)+2×(2×0.75ST)+2×0.75UEL 66 72 7600
3×50+3×(50+50/3)+2×(2×0.75ST)+2×0.75UEL 69 75 9200
3×70+3×(70+70/3)+2×(2×0.75ST)+2×0.75UEL 76 81 11150
3×95+3×(95+95/3)+2×(2×0.75ST)+2×0.75UEL 85 90 13300

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.