Products

NSSHCGEOEU Longwall Coal Cutter Cable(Low Tensile Stress)0.6/1KV

APPLICATION
These NSSHCGEOEU cables are used for the connection of mobile machines, predominantly in mining applications,e.g. for coal-cutting machines, suitable for extreme bending loads under low tensile stress.

NSSHCGEOEU Longwall Coal Cutter Cable(Low Tensile Stress)0.6/1KV

NSSHCGEOEU Coal Cutter Cable 0.6/1KV Application

NSSHCGEOEU Coal Cutter Cables are used for the connection of mobile machines under extremely high mechanical loads, predominantly in mining situations,e.g. for coal-cutting machines, suitable for extreme bending loads under low tensile stress.

The phase-concentric monitoring shield and the common concentric earth conductor, in conjunction with appropriate monitoring equipment, make it possible to monitor the cable for insulation faults and damage resulting from external influences. The cable can be delivered with 2, 3 or 6 pilot cores.

These NSSHCGEOEU cables comply with DIN VDE 0250 part 812 Standards.

NSSHCGEOEU Low Tensile Stress Coal Cutter Cable 0.6/1KV Construction

NSSHCGEOEU Low Tensile Stress Coal Cutter Cable 0.6 1KV Construction

Conductors Flexible stranded tinned copper conductor.
Insulation Heat resistant 3GI3 rubber based on EPR.
Outer Conductor Layer Easy stripable outer conductive layer.
Pilot Cores Copper strand and steel braid conductor capable of expansion and compression with EPRrubber insulation.
Monitoring Conductor Spiral of tinned copper wires above the pilot cores, covered with a semi-conductive tape.
InnerSheath Rubber type GM1b.
Armor/Earth Conductor Concentric earth conductor as the spiral of copper and steel wires, fiberglass tape, embedded in the outer sheath which prevents sheath exchanging.
Outer Sheath Rubber type 5GM5, abrasion, and tear-resistant, oil-resistant, and flame retardant.

NSSHCGEOEU Low Tensile Stress Coal Cutter Cable 0.6/1KV Technical Data

Rated Voltage Uo/U (Um) 0.6/1 kV
Max. conductor temperature in service 90°C
Max. short-circuit temperature of conductor: 200°C
Limit surface temperature fixed installed -40°C~ 80°C
Limit surface temperature, flexible application -25°C ~ 80°C
Oil resistance Yes
Flame retardant Yes
Dynamic bending radius 4(xD)
Static bending radius 1.5(xD)

NSSHCGEOEU Low Tensile Stress Coal Cutter Cable 0.6/1KV Specifications

Number of Cores×
Nominal Cross Section
Minimum
Overall Diameter
Maximum
Overall Diameter
Nominal
Weight
No.×mm² mm mm kg/km
3×16/16KON+2ST+UEL 35 38 2130
3×25/16KON+2ST+UEL 38 41 2790
3×35/16KON+2ST+UEL 41 45 3390
3×50/25KON+2ST+UEL 47 51 4340
3×70/35KON+2ST+UEL 52 56 5680
3×95/50KON+2ST+UEL 58 62 7180
3×25/16KON+3×(1.5ST+UEL) 38 41 2920
3×35/16KON+3×(1.5ST+UEL) 41 45 3630
3×50/25KON+3×(1.5ST+UEL) 45 48 4500
3×70/35KON+3×(1.5ST+UEL) 48 53 5850
3×95/50KON+3×(1.5ST+UEL) 52 56 7400
3×120/70KON+3×(1.5ST+UEL) 58 63 8300
3×150/70KON+3×(1.5ST+UEL) 62 68 9300

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.