EV Charging Cable
EV Charging Cable Application
The EV Charging Cable is intended for Electric Vehicle Charging Device and charging mouth, or for Electric Vehicle Charge-Discharge Early Warning System with control signals transmission function like charging saturation, early safety warning, and others.
The EV charging cable has super flexibility and the minimum bending radius is 6 times of OD and its easy to install and use. Its excellent thermal stress passed ISO 6722 high-temperature shock test. It also has excellent oil resistance performance, like gasoline, diesel oil, engine oil. This EV charging cable is strongly resistant to UV and it passes UL 2556 UV resistance test.
EV Charging Cable Construction
Conductor | Tinned or non-tinned stranded soft copper wire |
Insulation | 105℃ Halogen-free, ROHS thermoplastic elastomer TPE |
Signal wire screen(if any) | Tinned Annealed Flexible Copper wire braid |
Sheath | 105℃ Halogen-free, ROHS thermoplastic elastomer TPE Sheath Color: Black or Orange |
EV Charging Cable Technical Data
Rated Voltage | AC 300/500V; 450/750V DC1000V |
Rated Temperature | -40℃~105℃ |
Insulation resistance | ≧0.037MΩ.km at 60℃ |
Flame Retardant test | VW-1 test method comply with UL2556 |
Min Bending Radius | 6*OD |
Dielectric Voltage | AC2.5kV/15min no breakdown |
Cold bending | -40℃/16h no cracks |
Hot Shock | 150℃/1h no cracks |
Oil Resistance | IRM902,IRM903,Gasoline 20h OD Variation≦15%,No cracks. |
Acid and Alkali Resistance | 168h,Tensile Strength Change≦30%,Elongation≧100% |
Crash Resistance, Vehicle drive over | 5KN,8km.h,220Kpa,no breakdown |
Environment-friendly performance | Comply with ROHS and REACH |
EV Charging Cable Specification
EV Charing Cable Spec | Conductor Construction | DC Resistance at 20℃ | Outer Diameter |
mm2 | Nos/mm | Ω/km | mm |
EVDC-EE 2*25+16+2*4+2P*1.5 | Main wire:798/0.20 Grounding wire:513/0.2 Signal Wire:224/0.15 Shield:85/0.15 |
Main wire:0.795 Grounding wire:1.16 Signal Wire:4.71 Shield:12.7 |
30 |
EVDC-EE 2*50+16+2*4+2P*1.5 | Main wire:1586/0.20 Grounding wire:513/0.2 Signal Wire:224/0.15 Shield:85/0.15 |
Main wire:0.393 Grounding wire:1.16 Signal Wire:4.71 Shield:12.7 |
34 |
EVDC-EE 2*70+16+2*4+2P*1.5 | Main wire:1387/0.254 Grounding wire:513/0.2 Signal Wire:224/0.15 Shield:85/0.15 |
Main wire:0.277 Grounding wire:1.16 Signal Wire:4.71 Shield:12.7 |
36 |
Data above only for reference, confirmation needed by our technical department when ordered.
We reserve the right to alter all information without prior notice since technology improvement.
And we also can design and produce according to client’s special requirements.
please contact us for more information.
DISCLAIMER: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.