USE-2 600V PV Wire for Solar Applications
USE-2 600V PV Wire for Solar Applications
USE-2 PV wire a single conductor, cross-linked polyethylene (XLP/XLPE) Type of solid or stranded bare annealed copper. The insulation material is sunlight resistant and is designed to operate at up to 600 V.
Tough insulation that’s heat, moisture, oil, and gasoline resistant, withstands high temperatures and harsh conditions, and its black insulation resists ultraviolet sunlight very well, and can, therefore, be used with no issue in outside applications.
Our USE-2 is produced to the following specifications and requirements:
UL listed Type USE-2 600V; Type PV 600V;
UL Standard 854: Standard for Safety for Service Entrance Cables.
UL Standard 4703: Outline of Investigation for Photovoltaic Wire, PV Wire.
meets cold bend test at -40°C; UL sunlight resistant; UL VW-1 flame resistant.
ASTM B3 – Standard specification for soft or annealed copper wire.
ASTM B8 – Standard specification for concentric lay stranded copper conductors; hard, medium and soft.
RoHS compliant.
Available Products
- Sizes #14 through 1/0 AWG
- Solid or Stranded
- Up to 12 color options for all sizes
- Standard insulation is XLP, with XLP-VW-1 available when needed
- The standard product operates up to 600 V, with 1000 V (1kV) and 2000 V (2kV) RHW-2 capacity options available when needed
USE-2 600V PV Wire Construction
Conductor material: | Stranded bare copper or tinned copper, electrical Property & Structure in accordance with JIS C 3102 and JIS C 3152 flexible conductor |
Insulation: | LSZH electron-beam cross-linked Polyolefin copolymer, ROHS material |
Sheath: | XLPE, Sheath color: Black |
USE-2 600V PV Wire Technical Data
Rated Voltage U | 600V |
Test Voltage U | 18-10 awg ,U0=3000v ,50hz,1min 8-2 awg .Uo=3500v ,50hz ,1min 1-4 awg ,Uo=4000v ,50hz, 1 min |
Bending Radius | Fixed installation>4D; Occasionall moved>5D |
Rated Temperature | -40 Degree to +90 Degree |
Relative permittivity | UL 854 |
Cold bend test | UL 854 |
Flame retardance: | UL 1581 VW-1 |
Stability factor | UL 854 |
USE-2 600V PV Wire Specification
UL | Section Size |
Structure | XLPE Thickness |
Jacket OD |
Weight | Allow Current |
Conductor Resistance |
AWG | mm2 | mm | mm | kg / 100M | A / mm2 | Ω/km | |
14 | 2.08 | 41/0.254 TC | 1.15 | 4.2 | 3.2 | 27 | 9.07 |
13 | 2.5 | 49/0.254 TC | 1.15 | 4.3 | 3.6 | 29.6 | 7.35 |
12 | 3.3 | 65/0.254 TC | 1.15 | 4.6 | 4.5 | 35.9 | 5.71 |
11 | 4 | 56/0.30TC | 1.15 | 4.9 | 5.2 | 39.4 | 4.6 |
10 | 5.3 | 75/0.30 TC | 1.15 | 5.3 | 6.6 | 47.5 | 3.59 |
9 | 6 | 84/0.30 TC | 1.15 | 5.5 | 7.3 | 49.7 | 3.06 |
Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.