Products

TPNP JIS C 3410 Shipboard Portable Shore Cable

APPLICATION OVERVIEW

TPNP is intended for power,lighting and control system of shipboard and off-shore building where requires flexible or portable application.

TPNP JIS C 3410 Shipboard Portable Shore Cable

TPNP JIS C 3410 Shipboard Portable Shore Cable Application

TPNP is intended for power,lighting and control system of shipboard and off-shore building where requires flexible or portable application.

JIS C 3410 Shipboard Portable Shore Cable Standards and Designation

Designation:0.6/1kV DPNP, 0.6/1kV TPNP, 0.6/1kV FPNP
STANDARDS:JISC 3410-2010,IEC 60332-1

TPNP JIS C 3410 Shipboard Portable Shore Cable Construction

TPNP JIS C 3410 Shipboard Portable Shore Cable Construction

 

Conductor D(T,F) Tinned annealed stranded copper, class 5 according to IEC 60228
Insulation P 85°C EPR as per IEC 60092-351
Cabling Insulated conductors shall be cabled.
Flame retardant & non-hygroscopic fillers may be used
Sheath N PCP as per JIS C 3410
P Portable
Core identification 2C Black, White
3C Black, White, Red
4C Black, White, Red, Green
Outer sheath color Black

JIS C 3410 Shipboard Portable Shore Cable Specification

Cable Type Conductor Thick. of insulation Thick. of Sheath Nom. overall dia. Tolerance Cable Weight
Size Construction O.D
mm No./mm mm mm mm mm mm kg/km
DPNP 0.75 24/0.20 1.13 1 1.4 9.7 0.4 130
1 32/0.20 1.27 1 1.4 9.9 0.4 135
1.5 30/0.25 1.58 1 1.5 10.8 0.4 165
2.5 49/0.25 2.02 1 1.6 11.8 0.5 205
4 55/0.30 2.57 1 1.7 13.1 0.5 265
6 82/0.30 3.14 1 1.8 14.5 0.6 340
TPNP 0.75 24/0.20 1.13 1 1.4 10.2 0.4 145
1 32/0.20 1.27 1 1.5 10.7 0.4 160
1.5 30/0.25 1.58 1 1.5 11.4 0.5 190
2.5 49/0.25 2.02 1 1.6 12.5 0.5 240
4 55/0.30 2.57 1 1.8 14.1 0.6 325
6 82/0.30 3.14 1 1.9 15.6 0.6 420
FPNP 0.75 24/0.20 1.13 1 1.5 11.3 0.5 175
1 32/0.20 1.27 1 1.6 11.8 0.5 200
1.5 30/0.25 1.58 1 1.6 12.2 0.5 225
2.5 49/0.25 2.02 1 1.8 14.1 0.6 310
4 55/0.30 2.57 1 1.9 15.6 0.6 405
6 82/0.30 3.14 1 2 17.2 0.7 525