Solar Cable PV1-F EBXL Photovoltaic 600/1000V
Solar Cable PV1-F EBXL Photovoltaic 600/1000V Application
TÜV approved solar cable intended for the interconnection within photovoltaic systems such as solar panel arrays.For free movable or fixed installation in photovoltaic installations according to EN 60364-7-712. The cable may be used indoor, outdoor, in earth (please note the laying instruction), in explosion hazard areas in industry and agriculture. The cable is considered to short-circuit and earth-fault safe.
This solar cable is installed within conduit or systems, but not direct burial applications. Our solar cable is ozone-resistant according to BS EN 50396, UV resistant according to HD 605/A1, and is tested for durability according to EN 60216. The cable is designed to last at least 25 years.
Being flame protected with a halogen-free fire retardant system with low smoke properties.these cables are designed for safety in case of fire.
PV1-F EBXL Photovoltaic Solar Cable 600/1000V Construction
Conductor material: |
Bare copper strands Class 5 to IEC 60228 |
Insulation: |
Halogen-free electronic beam cross-linked compound |
Insulation: |
Halogen-free electronic beam cross-linked compound, Flame retardant |
PV1-F EBXL Photovoltaic Solar Cable 600/1000V Electric Performance
Rated Voltage U0/U |
0.6/1 kV AC; 0.9/1.5 kV DC |
Maximum Permitted DC Voltage |
1.8 kV DC (conductor/conductor, non-earthed system, circuit not under load) |
Insulation Resistance |
1000 MΩ-km |
Spark Test |
6000 VAC (8400 VDC) |
Voltage Withstand |
6500 VAC for 5 min |
PV1-F EBXL Photovoltaic Solar Cable 600/1000V Thermal Performance
Ambient Temperature |
-40℃ ~ +90℃ |
Maximum Temperature At Conductor |
120℃ (20000h) according to IEC/EN 60216-1 |
Short Circuit Temperature |
200℃/5 sec |
Thermal Endurance Test |
According to EN 60216-2 (temperature index +120° C) |
High Temperature Pressure Test |
According to EN 60811-3-1 |
Damp-Heat Resistance |
According to EN 60068-2-78 with 85% humidity |
PV1-F EBXL Photovoltaic Solar Cable 600/1000V Mechanical Performance
Minimum Bending Radius |
4×OD (fixed), 5×OD (flexing) |
Dynamic Penetration |
According to 2 PfG 1169/08.2007 Annex F |
Notch Propagation |
According to 2 PfG 1169/08.2007 Annex G |
Tensile Strength And Elongation Of Insulation And Jacket |
According to EN 60811 |
Anticipated Period Of Service |
25 years |
PV1-F EBXL Photovoltaic Solar Cable 600/1000V Chemical&Fire Performance
Ozone Resistance |
According to EN 50396 part 8.1.3 Method B |
Weathering- UV Resistance |
According to HD 605/A1 |
Acid & Alkaline Resistance |
According to EN 60811-2-1 (Oxal acid and sodium hydroxide) |
Flame retardant |
According to EN 50265-2-1, IEC 60332-1, VDE 0482-332-1-2, DIN EN 60332-1-2 |
Low smoke emission |
According to IEC 61034, EN 50268 |
Halogen free |
According to EN 50267-2-1, IEC 60754-1 |
Low corrosivity of gases |
According to EN 50267-2-2, IEC 60754-2 |
PV1-F EBXL Photovoltaic Solar Cable 600/1000V Specification
No. of Cores ×Nominal Cross Section |
No. of Stranding |
Nominal Overall Diamater |
Nominal Weight |
No. ×mm² |
– |
mm |
kg/km |
1×1.5 |
30/0.25 |
5.4 |
52 |
1×2.5 |
50/0.25 |
5.8 |
67 |
1×4.0 |
56/0.30 |
6.4 |
87 |
1×6.0 |
84/0.30 |
7.0 |
113 |
1×10 |
78/0.40 |
8.6 |
178 |
1×16 |
128/0.40 |
9.8 |
254 |
1×25 |
199/0.40 |
11.1 |
363 |
1×35 |
279/0.40 |
12.3 |
473 |
Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.