Products

MPYCYSLA Common Shielded Shipboard Control Cable

APPLICATION OVERVIEW
MPYCYSLA shipboard control and signal cable is used for fixed installation lighting & control in both explosion risk and safe areas, general purposes.

MPYCYSLA Common Shielded Shipboard Control Cable

MPYCYSLA Common Shielded Shipboard Control Cable Application

MPYCYSLA is intended for power circuit up to 250V, Lighting & Control circuit,also for fixed installation lighting & control in both explosion risk and safe areas, general purposes.

STANDARD APPLIED
Design guideline : JIS C 3410 (2010)
Material properties :
JIS C 3410 Insulation, EPR JIS C 3410 Sheath, PVC
Flame retardant :
IEC 60332-1
IEC 60332-3, Cat. A, ‘FA–’ type only
– Any other cable marking can be applicable, when purchaser required

MPYCYSLA Common Shielded Shipboard Control Cable Construction

MPYCYSLA Common Shielded Shipboard Control Cable Construction

 

Conductor M Tinned annealed stranded copper, class 2 according to IEC 60228
Insulation P 85°C EPR as per JIS C 3401
  Cabling Insulated conductors shall be cabled.
Flame retardant & non-hygroscopic fillers may be used
Overall shield SLA Overall Shielded with Aluminium foil-mylar tape and drain wire
Bedding Y PVC as per JIS C 3401
Armor C Galvanized steel wire braid
Sheath Y PVC as per JIS C 3401

MPYCYSLA Common Shielded Shipboard Control Cable Technical Data

Conductor cross-section 1mm²
Conductor diameter 1.3mm
Diameter over armour 1.0mm
Average insulation thickness 0.7mm
Rated Voltage Uo/U (Um) 150 / 250 V
Max. DC resistance of the conductor at 20°C 18.2Ohm/km
Test voltage 1500V

MPYCYSLA Common Shielded Shipboard Control Cable Specification

MPYCSLA,FA-MPYCSLA

No. of cores Conductor Nominal overall diam. Tolerance of diam.

over sheath

Cable weight

(Approx.)

Size Construction O.D
No. SQ No./mm mm mm ± mm kg/km
2 1 7/0.43 1.29 10.2 0.4 160
4 1 7/0.43 1.29 11.4 0.5 210
7 1 7/0.43 1.29 13.4 0.5 290
12 1 7/0.43 1.29 17 0.7 444
19 1 7/0.43 1.29 19.8 0.8 615
27 1 7/0.43 1.29 23.6 0.9 845
37 1 7/0.43 1.29 26.3 1.1 1070
44 1 7/0.43 1.29 29.5 1.2 1290

MPYCYSLA,FA-MPYCYSLA

No. of cores Conductor Nominal overall diam. Tolerance of diam. Cable weight
over sheath (Approx.)
Size Construction O.D
No. SQ No./mm mm mm ± mm kg/km
2 1 7/0.43 1.29 12 0.5 200
4 1 7/0.43 1.29 13.4 0.5 260
7 1 7/0.43 1.29 15.4 0.6 355
12 1 7/0.43 1.29 19.2 0.8 530
19 1 7/0.43 1.29 22.2 0.9 725
27 1 7/0.43 1.29 26.2 1 985
37 1 7/0.43 1.29 29.1 1.2 1240
44 1 7/0.43 1.29 32.5 1.3 1490