NSSHKCGEOEU Coal Cutter Cable 0.6/1KV
NSSHKCGEOEU Coal Cutter Cable 0.6/1KV Application
These NSSHKCGEOEU cables are intended for the connection of mobile machines under very high mechanical loads, predominantly for mining applications, e.g. for coal cutting machines, particularly suitable for extreme bending loads under low tensile stress.
This NSSHKCGEOEU cable is used as a power supply connection cable for mobile equipment in underground machine applications, such as coal shearer, road header, TBM`s, or scoops (LHDs). (Z)-Coal-Cutter cables are designed for free trailing operation and due to their special construction may be trailed for considerable distances behind the machine during operation.
The cable complies with the requirements of the Draft DIN VDE Test Standard 0472 Part 818 “Behaviour under Squeezing Stress”. It ensures that damage caused by squeezing is detected as earth faults with the highest possible reliability.
These NSSHKCGEOEU cables comply with DIN VDE 0250 part 812 Standards.
NSSHKCGEOEU Coal Cutter Cable 0.6/1KV Construction
Conductor | Particularly fine stranded copper conductor, tinned, Class 5 (refer also to DIN VDE 0295) |
Separator | Polyester tape |
Insulation: | heat-resistant Compound 3GI3 rubber compound on EPR basis with particularly high mechanical strength, colored |
Pilot core | copper/steel conductors capable of expansion and compression and insulating covering of EPR basis 3GI3. |
Core arrangement | Three main cores laid-up, with double-concentric control/monitoring conductor elements in the outer interstice; length of lay approx. 6 x D |
Inner sheath | Vulcanized rubber inner sheath; basic material EPR, compound type: GM1b |
Reinforcement/Armoring | Steel wire braid |
Outer sheath | basic material PCP, compound type: 5GM5, color yellow, abrasion, and tear resistant, oil resistant and flame retardant |
NSSHKCGEOEU Coal Cutter Cable 0.6/1KV Technical Data
Rated Voltage Uo/U (Um) | 0.6/1 kV |
Max. conductor temperature in service | 90°C |
Max. short-circuit temperature of conductor: | 250°C |
Limit surface temperature fixed installed | -40°C~ 80°C |
Limit surface temperature, flexible application | -25°C ~ 80°C |
Oil resistance | Yes, DIN VDE 0473, part 811-2-1, par. 10, EN 60811-2-1, IEC EN 60811-1-2 |
Flame retardant | Yes, DIN VDE 0482, EN/IEC 60332-1-2 |
Dynamic bending radius | 4(xD) |
Static bending radius | 1.5(xD) |
Weather resistance | Unrestricted use outdoors and indoors, resistant to ozone and moisture |
NSSHKCGEOEU Coal Cutter Cable 0.6/1KV Specification
No. of cores x cross section |
Max Conductor diameter |
Outer diameter min. |
Outer diameter max |
Cable weight approx. |
Tensile strength |
n x mm2 | mm | mm | mm | kg/km | N |
3×25+3x(1,5STKON +16/3KON) | 7.1 | 39.2 | 42.2 | 2700 | 3000 |
3×35+3x(1.5STKON+16/3KON) | 8.4 | 40.8 | 43.8 | 3100 | 4200 |
3×50+3x(1.5ST KÖN+25/3 KON) | 10.1 | 46.2 | 49.2 | 4000 | 5000 |
3×70+3x(1.5ST KÖN+35/3KON) | 11.9 | 49.6 | 53.6 | 5100 | 8400 |
3×95+3x(1,5STKON +50/3KON) | 14 | 56.8 | 60.8 | 5700 | 14440 |
3×120+3x(1,5STKON +70/3KON) | 15.5 | 60.6 | 64.6 | 8100 | 18000 |
3×150+3x(1,5STKON +70/3KON) | 17.6 | 67 | 71 | 9600 | 18000 |
3×185+3x(1,5STKON +95/3KON) | 19.1 | 72 | 76 | 11500 | 22000 |
3×240+3x(1,5STKON +120/3KON) | 22 | 80.4 | 85.4 | 14600 | 28800 |
3×300+3x(1,5STKON +150/3KON) | 24.8 | 89.1 | 94.1 | 18700 | 36000 |
Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.
Reviews