Conductor | bare Electrolytic copper, finely stranded, class 5 |
Insulation) | High-grade special compound based on high-quality EPR (at least GI3); improved mechanical and electrical characteristics |
Shield for individually shielded cores and twisted and shielded pairs | Braid screen made of tinned copper wires, transfer impedance optimized at 30 MHz.Surface covered: at least 60%: for individually shielded cores, at least 80%: for twisted and shielded pairs |
Core identification | Best identification as a result of light-colored insulation with numbers printed in black for power and control cables, earth conductor green/ yellow |
Core arrangement | Laid-up in a maximum of 3 layers |
Inner sheath | Basic material EPR, Rubber compound GM 1b Colour: black |
Outer sheath | High-grade special compound (at least 5GM3); based on PCP; Color: black |
NGRDGOEU Rubber Sheathed Festoon Bus Cable Code Designation
Code | Description |
N | VDE standard |
G | rubber insulation |
RD | round cable |
G | outer sheath constructed of rubber |
Ö | oil-resistant sheath material |
U | outer sheath with low flammability |
according to DIN VDE 0472 | |
-J | with a green/yellow identification of the earth/ground conductor |
-O | without a green/yellow identification of the earth/ground conductor |
NGRDGÖEU Rubber Sheathed Festoon Bus Cable Technical Data
Rated voltage | Uo/U = 0.6/1kV |
Max permissible operating voltage in AC systems | Uo/U = 0.7/1.2kV |
Max permissible operating voltage in DC systems | Uo/U = 0.9/1.8kV |
AC test voltage | 2.5 kV over 5 min |
Ambient temperature | |
Fully flexible operation Fixed installation |
-35℃ to +60℃ -50℃ to +80℃ |
Max permissible operating the temperature of the conductor |
90℃ |
Short-circuit temperature of the conductor | 250℃ |
Tensile load | Up to 15N/mm2 |
NGRDGOEU Rubber Sheathed Festoon Bus Cable Specification
Number of cores and
nominal cross-section |
Conductor
diameter |
Overall diameter of
cable Min. value |
Overall diameter of
cable Max. value |
Approx. net weight
for 1000 m |
Maximum permissible
tensile force |
mm | mm | mm | kg/km | N | |
(N)GRDGOEU – O bus cables | |||||
3x(2×1)C | 1.3 | 20.8 | 22.8 | 685 | 90 |
6x(2×0,5)C | 0.9 | 22.1 | 25.1 | 850 | 180 |
6x(2×1)C | 1.3 | 28.1 | 31.3 | 1250 | 180 |
9x(2×0,5)C | 0.9 | 28.3 | 31.3 | 1340 | 270 |
9x(2×1)C | 1.3 | 35.9 | 38.9 | 2010 | 270 |
12x(2×0,5)C | 0.9 | 29.8 | 32.8 | 1540 | 360 |
12×1(C) | 1.3 | 18 | 20 | 590 | 180 |
DISCLAIMER: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.