FR-TPYC JIS C3410 Shipboard Armored Power&Lighting Cable

APPLICATION OVERVIEW

FR-DPYC is intended for fixed installation for power,lighting on shipboard,marine,and oil,gas off-shore platform.

FR-TPYC JIS C3410 Shipboard Armored Power&Lighting Cable

FR-TPYC JIS C 3410 Shipboard Armored Power&Lighting Cable Application

FR-TPYC JIS C 3410 Shipboard Armored Power&Lighting Cable is intended for power,lighting on shipboard,marine,and oil,gas off-shore platform where requires fire resistant features to ensure man safe and circuit integrity.

JIS C 3410 Shipboard Armored Power&Lighting Cable Standards and Designation

Designation:FR-DPYC, FR-TPYC,FR-FPYC

STANDARDS:JISC 3410-2010,

Fire Resistant:IEC 60331

FR-TPYC JIS C3410 Shipboard Armored Power&Lighting Cable Construction

FR-TPYC JIS C3410 Shipboard Armored Power&Lighting Cable

 

Conductor D(T,F,5,6,10) Tinned annealed stranded copper, class 2 according to IEC 60228
Insulation P 85°C EPR as per JIS C 3401
Cabling Insulated conductors shall be cabled.
Flame retardant & non-hygroscopic fillers may be used
Bedding Y PVC as per JIS C 3401
Armor C Galvanized steel wire braid
Core identification 2C Black, White –
3C / 2C+E Black, White, Red/ Black, White, G/Y
4C / 3C+E Black, White, Red, Green /Black, White, Red, G/Y
5C and over Black No. on white insulation /Black No. on white insulation, G/Y
Outer sheath
color
Black

JIS C 3410 Shipboard Fire Resistant Power&Lighting Cable Specification

0.6/1KV FR-DPYC

Conductor Thick. of
insulation
Thick. of
bedding
Dia. of steel
wire
(FA-) DPYC
Size Construction O.D Nominal
overall
dia.
Tolerance Cable
weight
(Approx.)
mm² No./mm mm mm mm mm mm mm Kg / Km
1.5 7/0.53 1.59 1 1.1 0.3 11.7 0.5 205
2.5 7/0.67 2.01 1 1.2 0.3 12.8 0.5 250
4 7/0.85 2.55 1 1.2 0.3 13.9 0.6 300
6 7/1.04 3.12 1 1.3 0.3 15.2 0.6 370
10 7/1.35 4.05 1 1.3 0.3 17.1 0.7 490
16 7/1.70 5.1 1 1.4 0.3 19.4 0.8 660
25 7/2.14 6.42 1.2 1.5 0.3 23 0.9 945
35 7/2.52 7.56 1.2 1.6 0.3 25.5 1 1200
50 19/1.78 8.9 1.4 1.8 0.3 29.4 1.2 1580
70 19/2.14 10.7 1.6 2 0.4 35.1 1.4 2300
95 19/2.52 12.6 1.6 2.1 0.4 39.1 1.6 2960
120 37/2.03 14.2 1.6 2.3 0.4 42.7 1.6 3600
150 37/2.25 15.8 1.8 2.4 0.4 46.8 1.7 4330
185 37/2.52 17.6 2 2.6 0.4 51.8 1.9 5330

0.6/1KV FR-TPYC

Conductor Thick. of
insulation
Thick. of
bedding
Dia. of steel
wire
(FA-) TPYC
Size Construction O.D Nominal
overall
dia.
Tolerance Cable
weight
(Approx.)
mm² No./mm mm mm mm mm mm mm Kg / Km
1.5 7/0.53 1.59 1.0 1.2 0.3 12.5 0.5 245
2.5 7/0.67 2.01 1.0 1.2 0.3 13.5 0.5 295
4 7/0.85 2.55 1.0 1.2 0.3 14.7 0.6 365
6 7/1.04 3.12 1.0 1.3 0.3 16.1 0.6 455
10 7/1.35 4.05 1.0 1.4 0.3 18.3 0.7 625
16 7/1.70 5.1 1.0 1.5 0.3 20.8 0.8 855
25 7/2.14 6.42 1.2 1.6 0.3 24.7 1.0 1240
35 7/2.52 7.56 1.2 1.7 0.3 27.4 1.1 1600
50 19/1.78 8.9 1.4 1.9 0.4 32.0 1.3 2200
70 19/2.14 10.7 1.6 2.1 0.4 37.6 1.5 3050
95 19/2.52 12.6 1.6 2.2 0.4 41.9 1.6 3980
120 37/2.03 14.2 1.6 2.4 0.4 45.8 1.7 4860
150 37/2.25 15.8 1.8 2.5 0.4 50.2 1.8 5870
185 37/2.52 17.6 2.0 2.7 0.4 55.5 1.9 7230
240 61/2.25 20.25 2.2 3.0 0.4 62.7 2.3 10100

​0.6/1KV FR-FPYC

Conductor Thick. of
insulation
Thick. of
bedding
Dia. of steel
wire
(FA-) FPYC
Size Construction O.D Nominal
overall
dia.
Tolerance Cable
weight
(Approx.)
mm² No./mm mm mm mm mm mm mm Kg / Km
1.5 7/0.53 1.59 1.0 1.2 0.3 13.4 0.7 370
2.5 7/0.67 2.01 1.0 1.2 0.3 14.4 0.7 440
4 7/0.85 2.55 1.0 1.3 0.3 16.0 0.8 550
6 7/1.04 3.12 1.0 1.3 0.3 17.4 0.9 680
10 7/1.35 4.05 1.0 1.4 0.3 19.9 1.0 940
16 7/1.70 5.1 1.0 1.5 0.3 22.6 1.1 1280
25 7/2.14 6.42 1.2 1.7 0.3 27.3 1.4 1860
35 7/2.52 7.56 1.2 1.8 0.3 30.2 1.5 2400
50 19/1.78 8.9 1.4 2.0 0.4 35.6 1.8 3300
70 19/2.14 10.7 1.4 2.1 0.4 40.2 2.0 4580
95 19/2.52 12.6 1.6 2.4 0.4 46.5 2.3 5970
120 37/2.03 14.2 1.6 2.5 0.4 50.8 2.5 7290
150 37/2.25 15.8 1.8 2.7 0.4 56.1 2.8 8810
185 37/2.52 17.6 2.0 2.9 0.4 61.9 3.1 10850

For more specs,pls contact us.