NYCY PVC SCREENED PVC 0.6/1KV POWER CABLE
NYCY PVC SCREENED PVC 0.6/1KV POWER CABLE APPLICATION
NYCY cable is insulated, bound and sheathed in Polyvinyl Chloride (PVC), for use as a fixed wiring cable in installations indoors, in cable ducts, outdoors, and in-ground. It is used for power plants, industrial plants, and in local power networks, particularly if increased mechanical and electrical protection is required. It has a UV and water-resistant outer sheath.
Distribution and signalling power cable for static outdoor application (with protection against direct UV-irradiation), in-ground, in water, within facilities, in cable canals, in concrete, in conditions requiring increased electric protection and protection against mechanical damages. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and other electric plants and for connection of signalling devices in industry, traffic and similar. The concentric conductor can be used as neutral, protective or earth connection, and if there is a danger of damages caused by digging, it acts as protection against contact voltage in case of rough insulation damage.
NYCY PVC SCREENED PVC 0.6/1KV POWER CABLE CONSTRUCTION
Conductor: | Cu, class 1 acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295, solid, round (RE) | |
Insulation: | PVC compound DIV-4 acc. to HRN HD 603.1, concentrically stranded cores, colour marked acc. to HRN HD 308 S2 / VDE 0293-308, without a protective yellow-green conductor | |
Filler: | spouted elastomer or plastomer compound or wrapped thermoplastic tapes | |
Concentric conductor: | in inner layer round copper wires, in external layer copper tape wrapped in counter-helix | |
Sheath: | PVC compound DMV-5 acc. to HRN HD 603.1 | |
sheath colour: | black |
NYCY PVC SCREENED PVC 0.6/1KV POWER CABLE TECHNICAL DATA
Temperature range: | |
during installation: | -5 °C up to +50 °C |
fixed installed: | -30 °C up to +70 °C |
at short circuit of max. 5 s: | up to 160 °C |
Nominal voltage: | Uο/U = 0,6/1 kV |
Test voltage: | 4 kV |
Max. operating voltage in three-phase systems: | 1,2 kV |
Maximal tensile strength: | 50 N/mm² |
Behaviour in fire: | IEC 60332-1 |
Minimal inner bending radius: | |
single-core: | 15D |
multi-core: | 12D |
NYCY PVC SCREENED PVC 0.6/1KV POWER CABLE Specification
Number of cores
and mm² per conductor |
Outer
diameter(mm) |
Copper
index(kg/km) |
Weight(kg/km) |
2×1,5re/1,5 | 14 | 52 | 245 |
3×1,5re/1,5 | 14 | 66 | 280 |
4×1,5re/1,5 | 15 | 81 | 302 |
7×1,5re/2,5 | 17 | 133 | 450 |
12×1,5re/2,5 | 20 | 205 | 580 |
24×1,5re/6 | 26 | 413 | 1100 |
3×2,5re/2,5 | 15 | 104 | 316 |
4×2,5re/2,5 | 16 | 128 | 360 |
7×2,5re/2,5 | 18 | 200 | 530 |
16×2,5re/6 | 23 | 451 | 950 |
4x4re/4 | 18 | 200 | 485 |
4x6re/6 | 19 | 297 | 616 |
Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.