Products

USE-2 600V PV Wire for Solar Applications

APPLICATION OVERVIEW
USE-2 is suitable for all solar wiring solutions as interconnection wiring of grounded photovoltaic power systems.

USE-2 600V PV Wire for Solar Applications

USE-2 600V PV Wire for Solar Applications

USE-2 PV wire a single conductor, cross-linked polyethylene (XLP/XLPE) Type of solid or stranded bare annealed copper. The insulation material is sunlight resistant and is designed to operate at up to 600 V.

Tough insulation that’s heat, moisture, oil, and gasoline resistant, withstands high temperatures and harsh conditions, and its black insulation resists ultraviolet sunlight very well, and can, therefore, be used with no issue in outside applications.

Our USE-2 is produced to the following specifications and requirements:

UL listed Type USE-2 600V; Type PV 600V;

UL Standard 854: Standard for Safety for Service Entrance Cables.

UL Standard 4703: Outline of Investigation for Photovoltaic Wire, PV Wire.

meets cold bend test at -40°C; UL sunlight resistant; UL VW-1 flame resistant.

ASTM B3 – Standard specification for soft or annealed copper wire.

ASTM B8 – Standard specification for concentric lay stranded copper conductors; hard, medium and soft.

RoHS compliant.

Available Products

  • Sizes #14 through 1/0 AWG
  • Solid or Stranded
  • Up to 12 color options for all sizes
  • Standard insulation is XLP, with XLP-VW-1 available when needed
  • The standard product operates up to 600 V, with 1000 V (1kV) and 2000 V (2kV) RHW-2 capacity options available when needed

USE-2 600V PV Wire Construction

USE-2 600V PV Wire Construction

Conductor material: Stranded bare copper or tinned copper, electrical Property & Structure in accordance with JIS C 3102 and JIS C 3152 flexible conductor
Insulation: LSZH electron-beam cross-linked Polyolefin copolymer, ROHS material
Sheath: XLPE, Sheath color: Black

USE-2 600V PV Wire Technical Data

Rated Voltage U 600V
Test Voltage U 18-10 awg ,U0=3000v ,50hz,1min
8-2 awg .Uo=3500v ,50hz ,1min
1-4   awg ,Uo=4000v ,50hz, 1 min
Bending Radius Fixed installation>4D; Occasionall moved>5D
Rated Temperature -40 Degree to +90 Degree
Relative permittivity UL 854
Cold bend test UL 854
Flame retardance: UL 1581 VW-1
Stability factor UL 854

USE-2 600V PV Wire Specification

UL Section
Size
Structure XLPE
Thickness
Jacket
OD
Weight Allow
Current
Conductor
Resistance
AWG mm2 mm mm kg / 100M A / mm2 Ω/km
14 2.08 41/0.254 TC 1.15 4.2 3.2 27 9.07
13 2.5 49/0.254 TC 1.15 4.3 3.6 29.6 7.35
12 3.3 65/0.254 TC 1.15 4.6 4.5 35.9 5.71
11 4 56/0.30TC 1.15 4.9 5.2 39.4 4.6
10 5.3 75/0.30 TC 1.15 5.3 6.6 47.5 3.59
9 6 84/0.30 TC 1.15 5.5 7.3 49.7 3.06

Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.